Descriptions
The Capacitive Voltage Probe (CVP) is designed for measuring asymmetrical disturbances on cables with
capacitive coupling principle. It gives the opportunity to do the measuring without disconnection of the
tested cable (“in-situ”) and it avoids the infl uence of the transmission. Main parameter of the CVP is the
coupling factor, measured in a calibration system with 50 Ω impedance. The capacitive voltage probe is
specifi ed in chapter 5.2.2 and Annex G of CISPR 16-1-2. -
Highlights
-Frequency range: 150 kHz to 30 MHz
-RF voltage range (in relation to a noise fi gure of the receiver F ≤ 10 dB)
-Sinus voltage (Average, BIF = 9 kHz CISPR 16-1)
-Upper limit (A1, 1 dB- compression): 150 dBμV
-Lower limit (A3, f ≥ 1 MHz, noise error ≤ 1 dB): 26 dBμV
-Pulse voltage (Quasi- peak)
-Upper limit (A1, Puls frequency: 100 Hz): 74 dBμV
-Overload indicator: for sinus- and pulse voltages
-Correction factor k1 (Only valid for a cable diameter of 22 mm)
A3: 20 dB
A2: 30 dB
A1: 40 dB
-Frequency response correction factor k1
A3: ±0.5 dB
A2: ±0.5 dB
A1: ±1 dB
-Power supply
internal: 6 x 1.2 V, NiMH- Akku, e.g. 1700 mAh
external: linear power supply, 230 VAC / 9 VDC
DC current, typ.: 180 mA
-Battery life, typ.: 8 h
-Cable diameter
max: 32 mm
min: 5 mm
-Connectors
Output to the test receiver: BNC 50 Ω, female
Input power supply: jack bush, ∅ 3.5 mm -
Benefits
-CISPR 22 (EN 55022) compliant
-CISPR 16-1-2 compliant
-Battery or DC power supply
-Switchable conversion factor
-Shielded to reduce the direct capacitive coupling from local cables
-Calibration fixture included
-
Applications
我是中標題
CISPR 16-1-2
CISPR 22
CISPR 32
EN 61000-6-3
EN 61000-6-4